Model

150/30 RSOC Generator

System

RSOC Generator

RSOC Module with max. 40 Nm³/h Hydrogen output and max. 30 kWAC power output

Installation

20‘ ISO container

(RSOC module without auxiliary components)

 

Hydrogen Production

Performance

Power Input (100%) (AC)

150 kWAC ± 5 %

Hydrogen production (100%)

40 Nm³/h ± 5 %

Electrical efficiency (based on lower heating value of hydrogen)

>80 %

Dynamics

30…125 % hydrogen output (BoL)

 

Power Production

Performance

Power output (100%) (AC)

NG/CH4 operation: 25 kWAC ± 10 %

Hydrogen operation: 30 kWAC ± 10 %

Electrical efficiency (based on LHV)

NG/CH4 operation:

·         50 % +- 2 % points (full load)

·         55 % +- 2 % points (part load)

Hydrogen operation:

·         47 % +- 2 % points (full load)

·         53 % +- 2 % points (part load)

Other flammable gases possible

Dynamics

30…100 %